Real-time Power Widget & Dashboards

How dashboard widgets show sites that both draw power from the grid and send power back to it.

Written by Shir Goldstein

Updated at November 15th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting Started
  • Dashboard
  • TimeView
    Get started Work with the chart Understand your data Time & comparison Save & share Advanced
  • Energy Apps
  • Alerts & Notifications
  • Reports
  • Administration & Settings
  • Partners
  • Import & Exports
  • Mobile App
    Getting Started & Signing In Navigating the App The Site Dashboard and Its Widgets TimeView Lite Events (Optimize + Event Management) Notifications, alerts & push Preferences, Support & App Behavior
  • Plans & Packages
  • Security & Certification
  • Deployment
  • Hardware Manuals
  • Datasheets & Specs
  • Frequently Asked Questions (FAQ)
    Bridge FAQs PAN-10/PAN-12/PAN-14 Sensors FAQs PAN-42 Sensor FAQs Software Platform FAQs Package FAQs
  • Legal
  • What’s New
  • Bidirectional-Power
  • Energy Star Portfolio Manager
  • Panoramic AI
+ More

Table of Contents

What Is Bidirectional Power? Real-time Power Widget Energy Summary Whole-Site Widgets: Net, Imported, and Exported Group, Category, and Device Widgets: Net Only Last 7 Days Actual vs. Average Related Articles

What Is Bidirectional Power?

Quick refresher

A bidirectional PAN-42 sensor measures power in both directions:

  • Import - power drawn from the grid. Shown as positive, above zero.
  • Export - power sent back to the grid, for example solar surplus or a bidirectional EV charger. Shown as negative, below zero.

Net is import minus export. A negative net value means the site sent more power back than it drew.

For the full concept, see Bidirectional Power: What to Expect.

Real-time Power Widget

The widget formerly titled Real-time power consumption is now Real-time power.

The diverging gauge

On a bidirectional site, the gauge splits into two halves:

  • 0 sits at the top of the arc.
  • The right half fills toward your peak import.
  • The left half fills toward your peak export.
  • There is no needle. The active half fills toward your current value, and the other half stays empty.

The center shows your current net power. When you're exporting, the number has a leading minus sign. A colored dot and a label below it read Exporting or Importing.

On sites that also have generation devices (for example, PV/Solar), a second, thinner arc just inside the gauge shows what they're generating right now. This is on-site generation, not export.

How the gauge is scaled

The gauge ends are set from the highest hourly-average net power over the last 7 days — one end for import, one for export. If the site only imported (or only exported) during that week, both halves use the same scale so the gauge stays readable.

Because the scale uses hourly averages, a short spike can briefly read past the end of the arc.

Sites without bidirectional sensors keep the classic single 0-to-max gauge, unchanged.

Energy Summary

The summary panel next to the gauge shows energy for Last 24 hours, Last 7 days, and Last 30 days. Its header matches the site:

Site type Header
Bidirectional site Energy summary
Generation-only widget Energy generation summary
Classic (non-bidirectional) site Energy consumption summary

What each row shows depends on what the widget measures.

Whole-Site Widgets: Net, Imported, and Exported

When the widget measures the whole site, each period row shows three values:

  • Net - imported minus exported. Negative when the site was a net exporter for that period.
  • Imported (↓ arrow) - energy drawn from the grid.
  • Exported (↑ arrow) - energy sent back to the grid.

Imported and Exported are always shown without a sign. The arrow and color carry the direction. Only Net carries a minus sign.

On wider widgets, a thin bar under each row shows the imported/exported share. A legend at the bottom of the panel explains the arrows. Hover the info icon next to % vs prev period for what the trend compares.

Row details on hover

Hover over a row to open a details panel for that period:

  • Imported - Energy drawn from the grid, with its value.
  • Exported - Energy sent back to the grid, with its value.
  • The import/export split as a percentage.
  • Net - Imported minus exported. When Net is negative, the panel adds: This period exported more energy than it imported.
  • Imported vs prev period - the trend, when shown.

Trend arrows

The trend compares imported energy against the previous period of the same length. It doesn't use Net, because Net can cross zero and make a percentage meaningless.

Group, Category, and Device Widgets: Net Only

When the widget measures part of the site - a group, a category, or a device - each row shows a single signed net value. If the value is negative, an Export tag appears next to it.

Why the difference? Imported and exported totals only add up to something meaningful at the point where the site meets the grid. Across an arbitrary set of circuits, both can grow large while net stays small, so PowerRadar shows net only.

The trend arrow on these rows is hidden when it wouldn't be meaningful:

  • The previous period was zero or below, or
  • The current and previous values fall on opposite sides of zero.

Heads up:

  • Hover only. The row details panel opens on mouse hover. It isn't available by tapping on tablets.

Last 7 Days

On a bidirectional site, exported power appears as negative values on the Consumed line, below zero. It isn't a separate series. The Consumed total is a signed net figure, so it can be negative for a week of net export.

A separate Generated total and line appear only if the site also has generation devices set up, such as solar inverters configured as generation. That data comes from those devices, not from PAN-42 export.

Actual vs. Average

  • Supports negative values on bidirectional sites.
  • Hides the goal badge when the difference from average isn't meaningful - for example, during a net-export period.

Note: Widget trend arrows compare against the size of the previous period, ignoring its sign. A negative previous period won't flip the trend's direction.

Related Articles

  • Bidirectional Power: What to Expect
  • Bidirectional Power in TimeView
  • Bidirectional Power - FAQ & Known Limitations
power dashboard bidirectional real-time power gauge energy summary imported exported net pan-42 last 7 days actual vs average

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Your Site Dashboard at a Glance
  • Site Dashboard Widgets Reference
  • Chart Series Add-ons & PAN-42 Metrics
Expand